Products Description
The integrated shutter box is made of high-quality UV-resistant material, with small size, light weight, good linearity, good waterproof performance and long service life. It is widely used in meteorology, environmental protection, agriculture, scientific research, highways, construction sites, industry, forestry and other departments. It is used to measure parameters such as carbon dioxide, temperature and humidity, light, and atmospheric pressure.
Product Features
●Strong anti-interference ability, with watchdog circuit and automatic reset function to ensure stable operation of the system
● High integration, no moving parts, zero wear
● Maintenance-free, no need for on-site calibration
●ASA engineering plastics are used for outdoor applications without discoloration all year round
● The product design output signal is standardly equipped with RS485 communication interface (MODBUS protocol); 232, USB, Ethernet interface are optional, supporting real-time data reading
● Optional wireless transmission module, minimum transmission interval 1 minute
Product Specification
Measurement parameters | Carbon dioxide concentration |
Measuring range | 0~5000ppm |
Accuracy | 75ppm ± 3% measured value (25ºC) |
Resolution | 1ppm |
Output signal | RS485 (standard Modbus-RTU protocol, device default address: 01) |
Supply voltage | 3.6~12VDC |
Standby current | ≤5μA |
Working current | ≤30mA |
Maximum Power | ≤0.1W |
Operating temperature | 0ºC~50ºC |
Product Dimensions
Product Features
●Strong anti-interference ability, with watchdog circuit and automatic reset function to ensure stable operation of the system
● High integration, no moving parts, zero wear
● Maintenance-free, no need for on-site calibration
●ASA engineering plastics are used for outdoor applications without discoloration all year round
● The product design output signal is standardly equipped with RS485 communication interface (MODBUS protocol); 232, USB, Ethernet interface are optional, supporting real-time data reading
● Optional wireless transmission module, minimum transmission interval 1 minute
Product Dimensions
Product Specification
Measurement parameters | Carbon dioxide concentration |
Measuring range | 0~5000ppm |
Accuracy | 75ppm ± 3% measured value (25ºC) |
Resolution | 1ppm |
Output signal | RS485 (standard Modbus-RTU protocol, device default address: 01) |
Supply voltage | 3.6~12VDC |
Standby current | ≤5μA |
Working current | ≤30mA |
Maximum Power | ≤0.1W |
Operating temperature | 0ºC~50ºC |