Products Description
Scope of application
●Weather monitoring
●Urban environmental monitoring
●Wind power
●Sailing Ships
●Aviation Airport
●Bridges and Tunnels
Product Features
●High and low temperature resistance
●Good thermoplasticity and weathering resistance
●Impact resistance
●Compact size
●Fast response time
●High precision
●Wide range of applications
●High data transmission efficiency
Product Specification
Wind speed measurement range | 0~30m/s,0~50m/s,0~60m/s,(Other ranges can also be customized) |
Wind direction measurement range | 0~360° |
Start wind speed | ≤ 0.3m/s |
Accuracy | ± (0.3+0.03V) m/s, ± 1 ° |
Output signal | A: Voltage signal (choose one from 0~2V, 0~5V, 0~10V) |
B: 4~20mA (current loop) | |
C: RS485 (standard Modbus RTU protocol, default device address: 01) | |
D: SDI-12 (Serial Data Communication Interface Protocol of American Hydrological Organization) | |
power supply voltage (red and black lines) | 5~24VDC (when the output signal is 0~2V, RS485, SDI-12) |
12~24VDC (when the output signal is 0~5V, 0~10V, 4~20mA) | |
Heating power supply voltage (brown white line) | 12~24VDC |
Heating power | 160mA@12V; 310mA@24V |
Stability time | <1 s |
Response time | <1 s |
Working environment | Temperature: 0 ° C~50 ° C; Humidity:<95% RH |
Storage environment | Temperature: 0 ° C~50 ° C; Humidity:<95% RH |

Product Dimensions
Product Features
●High and low temperature resistance
●Good thermoplasticity and weathering resistance
●Impact resistance
●Compact size
●Fast response time
●High precision
●Wide range of applications
●High data transmission efficiency
Product Dimensions
Product Specification
Wind speed measurement range | 0~30m/s,0~50m/s,0~60m/s,(Other ranges can also be customized) |
Wind direction measurement range | 0~360° |
Start wind speed | ≤ 0.3m/s |
Accuracy | ± (0.3+0.03V) m/s, ± 1 ° |
Output signal | A: Voltage signal (choose one from 0~2V, 0~5V, 0~10V) |
B: 4~20mA (current loop) | |
C: RS485 (standard Modbus RTU protocol, default device address: 01) | |
D: SDI-12 (Serial Data Communication Interface Protocol of American Hydrological Organization) | |
power supply voltage (red and black lines) | 5~24VDC (when the output signal is 0~2V, RS485, SDI-12) |
12~24VDC (when the output signal is 0~5V, 0~10V, 4~20mA) | |
Heating power supply voltage (brown white line) | 12~24VDC |
Heating power | 160mA@12V; 310mA@24V |
Stability time | <1 s |
Response time | <1 s |
Working environment | Temperature: 0 ° C~50 ° C; Humidity:<95% RH |
Storage environment | Temperature: 0 ° C~50 ° C; Humidity:<95% RH |