Atech GPRS IOT lora wireless electromagnetic water flow meter

Atech GPRS IOT lora wireless electromagnetic water flow meter

High pressure sensor with PFA liner, is resistant to high pressure and negative pressure, and available to chemistry and corrosive solution.

GPRS communication supports two modes of TCP and UDP, and supports two connection modes of IP address and dynamic domain name.

Integration of acquisition and transmission, improving system reliability and reducing costs;

Do not crash, automatically restore after dropped calls;

Send Inquiry
Products Description

 

Intelligent electromagnetic flow meter is hallmarked by its high performance,and reliability based on successful, field-proven technology.It is being widely used in industries such as petroleum, chemical engineering,iron and steel, food, electricpower, paper making, water treatment,petrochemical, medicine etc.


Product Features

 

High pressure sensor with PFA liner, is resistant to high pressure and negative pressure, and available to chemistry and corrosive solution.

GPRS communication supports two modes of TCP and UDP, and supports two connection modes of IP address and dynamic domain name.

Integration of acquisition and transmission, improving system reliability and reducing costs;

Do not crash, automatically restore after dropped calls;

GPRS remote online setting and short message remote setting function;

Provide user setting software, open interface

Good waterproof performance


 

Product Specification

 

Main powerAC220V 50HZ / DC24V  
Power consumption<15W (And set with sensor supporting power consumption )
Display and push buttonsThe big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display ,four thin-film touch nubs ,which is used to data set .
AccumulatorForward total quantity ,reverse total quantity
Output signalAnalog outputBi-direction with two ways ,Isolation 0-10mA/4-20mA
Load resistor:0-10Ma;0-1.5KΩ;4-20Ma;0-750Ω
Frequency outputForward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on
Alarm outputTwo outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits.
Pulse outputFor pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P .The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on .
Accuracy±0.5% of the value displayed ,±0.3% or ±0.2% are selectable.
Damping time constantContinuous variable from 0-100 s (90%)can be selected by group
CommunicationRS232 ,RS485 or HART Communication are selectable ,with lighting resistance, GPRS output
Power failureAn anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years)
Protection classIP65, IP68
Ex-proof MarkExd[ia]ia‖Ct5

 

Product Dimensions

 

Product Features

 

High pressure sensor with PFA liner, is resistant to high pressure and negative pressure, and available to chemistry and corrosive solution.

GPRS communication supports two modes of TCP and UDP, and supports two connection modes of IP address and dynamic domain name.

Integration of acquisition and transmission, improving system reliability and reducing costs;

Do not crash, automatically restore after dropped calls;

GPRS remote online setting and short message remote setting function;

Provide user setting software, open interface

Good waterproof performance


 

Product Dimensions
Product Specification

 

Main powerAC220V 50HZ / DC24V  
Power consumption<15W (And set with sensor supporting power consumption )
Display and push buttonsThe big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display ,four thin-film touch nubs ,which is used to data set .
AccumulatorForward total quantity ,reverse total quantity
Output signalAnalog outputBi-direction with two ways ,Isolation 0-10mA/4-20mA
Load resistor:0-10Ma;0-1.5KΩ;4-20Ma;0-750Ω
Frequency outputForward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on
Alarm outputTwo outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits.
Pulse outputFor pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P .The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on .
Accuracy±0.5% of the value displayed ,±0.3% or ±0.2% are selectable.
Damping time constantContinuous variable from 0-100 s (90%)can be selected by group
CommunicationRS232 ,RS485 or HART Communication are selectable ,with lighting resistance, GPRS output
Power failureAn anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years)
Protection classIP65, IP68
Ex-proof MarkExd[ia]ia‖Ct5