Industrial Online Ph Controller Online Ph/orp Analyzer with Ph Electrode

Industrial Online Ph Controller Online Ph/orp Analyzer with Ph Electrode

It is widely used in wastewater treatment, pure water, circulating water, boiler water system, etc. 

Feature

1.The newly designed housing is waterproof, moisture- proof and dust-proof.

2.It has automatic cleaning function, and the cleaning device (optional) is in tap water cleaning mode.
3.Two channels 4-20mA, corresponding to temperature and PH respectively.
4.The product has high precision, high stability and strong anti-interference ability.

Send Inquiry
Products Description

 

It is widely used in wastewater treatment, pure water, circulating water, boiler water system, etc. And online monitoring of ORP value, such as electronics, aquaculture, food, printing and dyeing, electroplating, pharmaceutical, fermentation and chemical processes. It is very powerful in the application of remote systems and environmental monitoring of surface water and pollution source discharge.


Product Features

 

main feature

The newly designed housing is waterproof, moisture-proof and dust-proof.

It has automatic cleaning function, and the cleaning device (optional) is in tap water cleaning mode.

Two channels 4-20mA, corresponding to temperature and PH respectively.

The product has high precision, high stability and strong anti-interference ability.

Large dot matrix LCD screen, supports English operation menu, and displays multiple parameters simultaneously.

Automatic temperature compensation and adjustable pH and temperature values

Communication function: Opto-isolated 4-20 mA current output, the corresponding value can be freely set.

You can choose to use our company's host online acquisition software to collect and process data

Historical curve: PH mode can record 50 sets of historical data (sampling interval 1-240 minutes), and has query function.

Automatically identify standard solutions and restore to factory settings.

Watchdog function: ensures that the instrument has not crashed

Power failure protection > 10 years

 

Product Specification

 

Technical Parameters

Measuring range

0-14 ph -1999 ~ + 1999mV (ORP), 0 ~ 130.0 ℃

resolution

1mV, 0.1℃

Accuracy

± 1mV, ± 0.3℃

stability

≤ 0.01mV/24 hours

Control interface

Two sets of on-off relay contacts are divided into high and low alarm control

Automatic cleaning interface

A set of automatic cleaning control points, the cleaning time is 0-9999 seconds, the interval is 0-9999 minutes

Analog Output

Primary current output, photoelectric isolation protection, improved anti-interference ability, corresponding to the (4-20)mA range can be reverse output.

RS-485 interface

Opto-isolated output, support link, (partial compatibility with MODBUS protocol.)

Relay

The relay hysteresis value can be freely set, the relay load is 3A 220VAC

Working conditions

Ambient temperature 0 ~ 60 ℃, relative humidity ≤ 90%

Output Load

Load <750 Ω

Protection level

IP57


 

Product Dimensions

 

Product Features

 

main feature

The newly designed housing is waterproof, moisture-proof and dust-proof.

It has automatic cleaning function, and the cleaning device (optional) is in tap water cleaning mode.

Two channels 4-20mA, corresponding to temperature and PH respectively.

The product has high precision, high stability and strong anti-interference ability.

Large dot matrix LCD screen, supports English operation menu, and displays multiple parameters simultaneously.

Automatic temperature compensation and adjustable pH and temperature values

Communication function: Opto-isolated 4-20 mA current output, the corresponding value can be freely set.

You can choose to use our company's host online acquisition software to collect and process data

Historical curve: PH mode can record 50 sets of historical data (sampling interval 1-240 minutes), and has query function.

Automatically identify standard solutions and restore to factory settings.

Watchdog function: ensures that the instrument has not crashed

Power failure protection > 10 years

 

Product Dimensions
Product Specification

 

Technical Parameters

Measuring range

0-14 ph -1999 ~ + 1999mV (ORP), 0 ~ 130.0 ℃

resolution

1mV, 0.1℃

Accuracy

± 1mV, ± 0.3℃

stability

≤ 0.01mV/24 hours

Control interface

Two sets of on-off relay contacts are divided into high and low alarm control

Automatic cleaning interface

A set of automatic cleaning control points, the cleaning time is 0-9999 seconds, the interval is 0-9999 minutes

Analog Output

Primary current output, photoelectric isolation protection, improved anti-interference ability, corresponding to the (4-20)mA range can be reverse output.

RS-485 interface

Opto-isolated output, support link, (partial compatibility with MODBUS protocol.)

Relay

The relay hysteresis value can be freely set, the relay load is 3A 220VAC

Working conditions

Ambient temperature 0 ~ 60 ℃, relative humidity ≤ 90%

Output Load

Load <750 Ω

Protection level

IP57