Dissolved Oxygen Meter

Dissolved Oxygen Meter

● Dissolved oxygen measurement range is 0~20mg/L (0~200% saturation).
● The Modbus communication address can be set, and the baud rate can be modified.
● The dissolved oxygen sensor uses a wide voltage power supply, DC 10~30V can be.
● The principle of fluorescence measurement is adopted, no oxygen is consumed, and no electrolyte is required.
● Free cloud platform for the data view.
Send Inquiry
Products Description

 

Our dissolved oxygen meter is a device for measuring the concentration of dissolved oxygen in water. It adopts the principle of fluorescence measurement, does not consume oxygen, and does not require electrolytes. The dissolved oxygen measurement range is 0~20mg/L. Built-in temperature transmitter with automatic temperature compensation function.
Product Features

 

● Dissolved oxygen measurement range is 0~20mg/L (0~200% saturation).
● The Modbus communication address can be set, and the baud rate can be modified.
● The dissolved oxygen sensor uses a wide voltage power supply, DC 10~30V can be.
● The principle of fluorescence measurement is adopted, no oxygen is consumed, and no electrolyte is required.
● Free cloud platform for the data view.

 

Product Specification

 

Power supplyDC 10~30V
Power consumption0.2W
Measuring principlefluorescence method
Measuring range0~20mg/L (0~200% saturation)
Measurement error±3%FS; ±0.5°C (25°C)
Resolution0.01mg/L; 0.1%; 0.1°C
Response time≤60sec
Equipment working conditions0~40°C
Output modeRS485
Fluorescent film life1 year in normal use
Storage conditions-10~60°C
Electrode wire lengthdefault 5m
Shell materialpolyoxymethylene (POM), stainless steel

 

Product Dimensions

 

Product Features

 

● Dissolved oxygen measurement range is 0~20mg/L (0~200% saturation).
● The Modbus communication address can be set, and the baud rate can be modified.
● The dissolved oxygen sensor uses a wide voltage power supply, DC 10~30V can be.
● The principle of fluorescence measurement is adopted, no oxygen is consumed, and no electrolyte is required.
● Free cloud platform for the data view.

 

Product Dimensions
Product Specification

 

Power supplyDC 10~30V
Power consumption0.2W
Measuring principlefluorescence method
Measuring range0~20mg/L (0~200% saturation)
Measurement error±3%FS; ±0.5°C (25°C)
Resolution0.01mg/L; 0.1%; 0.1°C
Response time≤60sec
Equipment working conditions0~40°C
Output modeRS485
Fluorescent film life1 year in normal use
Storage conditions-10~60°C
Electrode wire lengthdefault 5m
Shell materialpolyoxymethylene (POM), stainless steel